This  Compressor Station was installed in two Phases. The compressor station was designed for unmanned operation (day time personnel only, not remote unmanned operation).The design made maximum use of modularized components to minimize on-site welding, use of foundations, and overall installation requirements.

Design Parameters

Design Pressure Suction                 1440 psig at 1200F
Design Pressure Discharge             1440 psig at 1200F
Corrosion Allowance                                                  0”
Minimum Design Temperature                           -200F

Scroll back and forth over the images to see the engineering drawings transform into the final product.